Looser Tolerance Required for Temperature Response Tests of Double Filters Under Coronal Abundance #358

Description

@joyvelasquez

Tests for the following double filter combinations:

  • Al-poly/Ti-poly

  • C-poly/Ti-poly

fail when using the default tolerance settings (rtol=0.005, atol=1e-6 * max). These failures only occur under the coronal abundance model, while the same filters pass under both photospheric and hybrid abundances.

As a temporary workaround, we’ve loosened the absolute tolerance to 1e-4 for these filters only under coronal conditions in the test suite. Revisit the tolerance once the source is clearly understood. Orginal PR #356