Skip to content

fix(installer): preserve finite GUI failure diagnostics - #958

Merged
antropos17 merged 1 commit into
masterfrom
codex/preserve-gui-failure-diagnostics-20261016
Oct 16, 2026
Merged

antropos17 merged 1 commit into
masterfrom
codex/preserve-gui-failure-diagnostics-20261016

Conversation

@antropos17

Copy link
Copy Markdown
Owner

Known GUI-helper failures currently become a generic publication refusal in the administrative journal receipt because their existing fixed codes and native operation identifiers are missing from the diagnostic allowlists.

Add the six existing GUI codes and three emitted operations to those literal lists. Exception traversal depth, precedence, exact type checks, same-cause Win32 pairing, first-failure retention and the closed receipt shape remain unchanged.

Validation: the real metadata-helper failure first reproduced the lost operation, then passed through the administrative receipt after this change. All 28 installer tests and five selected GUI controls pass; 37 unrelated GUI controls were excluded by the filter. The synthetic diagnostic matrix has 27 cases within one grouped test, including private-data exclusion, exact Int32 pairing and depth boundaries. A real malformed-manifest helper control also passes. Formatting and lint pass. Actual metadata failure has null Win32; numeric Win32 controls are explicitly synthetic. No native helper, authority seam, runtime activation or acceptance status changes.

@antropos17
antropos17 merged commit e9a39da into master Oct 16, 2026
5 checks passed
@antropos17
antropos17 deleted the codex/preserve-gui-failure-diagnostics-20261016 branch October 16, 2026 16:55
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment