Skip to content
This repository was archived by the owner on Mar 25, 2025. It is now read-only.
This repository was archived by the owner on Mar 25, 2025. It is now read-only.

[BUG] TcoCognexVision.TcoInsight_v_5_x_x does not write userdata back to the hardware #752

Description

@KrisztianOlah

Describe the bug
When using SetUserDataAsString(string,uint) or SetUserDataAsByte(byte,uint) the data will show correct values on the hmi, but not on the hardware, thus no data is sent to camera.

To Reproduce
Map camera, plug in correct hw structure to component.
Call either of the above methods.
Check data on ethercat I/O structure

Expected behavior
Expected would be that the component updates the physical outputs without further action.

Current workaround:
FOR i :=0 TO 63 DO GVL_Profinet.Cam_30.UserData.UserData[i] := Components.Insight._userData.UserData[i]; END_FOR

Additional context
Using latest published version of TcOpen (0.11.0-alpha.79).