8 changes: 5 additions & 3 deletions src/MeshWeaver.Hosting/ActiveCircuitTracker.cs
Original file line number Diff line number Diff line change
Expand Up @@ -36,9 +36,11 @@ public sealed class ActiveCircuitTracker

/// <summary>
/// Records a circuit closing. Clamped at zero: a double-close (Blazor can report a circuit
/// closed after a connection-down that already ended it) must never push the count negative —
/// a negative count reads as "drained" forever after, which would hand back the very kill this
/// exists to prevent.
/// closed after a connection-down that already ended it) must never push the count negative.
/// <see cref="Drained"/> is <c>Count == 0</c>, so a negative count reads as "still busy" and
/// the pod would sit out its whole grace period on every roll before being SIGKILLed — and
/// then the NEXT open would only bring it back to zero, so a live session would read as
/// drained and get cut off. Both directions are wrong; the clamp removes both.