2 changes: 2 additions & 0 deletions .coderabbit.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -25,3 +25,5 @@ reviews:
# and they are the least likely place for a shipped bug. Re-include them
# for a PR that is mostly test work.
- "!test/**"
auto_review:
drafts: true
198 changes: 198 additions & 0 deletions docs/proposals/whoop-spo2.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,198 @@
# Proposal: WHOOP SpO2 (blood oxygen) — evidence review and staged plan

Status: proposal only, no code yet. Written so other contributors can build on
the current state of `protocol` and `edge` without re-doing this research.

## Process (what was done, openly)

1. Reviewed `christianmeurer/whoop-reader` (MIT) end to end: 96-byte realtime
packet on the data characteristic, SpO2 claimed at byte 5 (range gate 50–100),
CRC-32 (poly 0x04C11DB7, xor-out 0xF43F44AC) at bytes 92–95.
2. Cross-checked against the community sources it cites
(jogolden/whoomp, bWanShiTong/reverse-engineering-whoop) and against current
open-source projects: ryanbr/noop ecosystem (issues #103, #2814, PRs #73, #11),
LeonardSEO/wearable5.0, rusheelraj.com/blog/whoop, Gadgetbridge issue #5731.
3. Compared with what our own repos already know: `protocol` (`live.dart`,
`records.dart`, `gen5_records.dart`), `whoop-rs` (`whoop-protocol/src/live.rs`,
`spo2_from_paired`, v18 `spo2_pct`), `edge` (`ble_engine.dart`,
`adapters/whoop_gen4.dart`, `adapters/signals.dart`).

What was NOT done: no real-device captures, no ground-truth comparison against a
reference oximeter, no CRC verification against our own captures. Everything
below that is not marked "verified in our repos" is community knowledge with
the confidence level stated.

## Findings by generation

### WHOOP 4.0 — no secured SpO2

- whoop-reader decodes byte 5 of the 96-byte realtime packet as SpO2 %.
Single source, no ground truth, only a 50–100 plausibility gate.
- The original reverse-engineering author states blood oxygen on the 4.0 is
"only measured once a day, during sleep" — so byte 5 is expected to carry a
value only inside sleep windows and 0/invalid otherwise.
- Our `protocol` repo verified that `spo2RedRaw`/`spo2IrRaw` (inner 64/66) move
in lockstep with a fixed offset: a red/IR ratio from them tracks channel drift,
not oxygenation (`records.dart` explicitly forbids building SpO2 on them).
noop documents the same fields as "raw ADC; SpO2 % computed server-side".
whoop-rs therefore only computes a ratio-of-ratios estimate on paired v24
windows and never a calibrated %.
- Open discrepancy: whoop-reader maps the data stream to characteristic
`61080004-…`, while whoop-rs maps `GEN4_DATA` to `61080005-…` and `…0004` to
EVENTS (`whoop-client/src/uuids.rs`). One mapping is off by one; must be
resolved against our own captures before any wiring.
- Constraint from edge AGENTS.md invariant 14: live high-rate streams are
RAM-only, never persisted. That rules out persisting the stream, NOT a
day metric: an in-memory aggregate over a validated sleep window can still
produce a nightly value without persisting anything. Whether Gen4 ever gets
a nightly metric is decided by validation + coverage, not by invariant 14
alone.

### WHOOP 5.0 / MG — community-reported app agreement, sleep-only

- v18 historical records carry the strap's own computed SpO2 % at frame-abs

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

⚪ Low · Opaque byte is assigned SpO2 semantics

When a contributor uses this proposal to implement the byte-82 interpretation before its encoding is established, contributors following these findings can treat the byte as a device-reported percentage and strip a purported status flag, despite the current payload contract explicitly refusing that interpretation. A follow-on decoder could publish unsupported SpO2 values.

Describe byte 82 as uninterpreted raw data, and present the percentage and flag interpretations only as unverified hypotheses pending captures.

Also at docs/proposals/whoop-spo2.md:63-64.

Prompt for AI agents
In `docs/proposals/whoop-spo2.md` at line 50:

**Opaque byte is assigned SpO2 semantics**

When a contributor uses this proposal to implement the byte-82 interpretation before its encoding is established, contributors following these findings can treat the byte as a device-reported percentage and strip a purported status flag, despite the current payload contract explicitly refusing that interpretation. A follow-on decoder could publish unsupported SpO2 values.

Describe byte 82 as uninterpreted raw data, and present the percentage and flag interpretations only as unverified hypotheses pending captures.

Also at `docs/proposals/whoop-spo2.md:63-64`.

byte 82 (= `inner[74]`), which our `protocol` already exposes as
`spo2CandidateRaw` (`gen5_records.dart`) but deliberately does not publish as
a percentage.
- Measurement schedule, confirmed independently by noop#2814, noop#73 and
wearable5.0 (FINDINGS §13): 30 s measurement bursts every 1,200 s, only while
the band declares sleep. 5/MG never sends red/IR raw channels (noop#11).
- Validation against the vendor app (noop#73): nightly means 93.4–96.7 vs
WHOOP's own 93.1–96.5 over the same weeks (period means 94.4 vs 94.8). No
night had both readings, so this stays an estimate, not a validation.
- No usable offline derivation from raw PPG on 5.0: time multiplexing alone
would NOT make SpO2 impossible (pulse oximeters alternate red/IR), but the
decoded Gen5 data has no identified red/IR channel pair and the optical
channel bursts are widely separated in time — so no derivation path is
available from what we can decode. The byte-82 device value is the only
usable source.
- Encoding not fully pinned: values above 128 appear to decompose as
`128 + value` with bit 7 acting as a flag/status bit. This is why
`spo2Candidate` is deprecated.

## Self-critical assessment

- "Matches the WHOOP app" is agreement, not validation; only a reference
oximeter (or PSG-grade device) validates. We state this explicitly, following
the precedent in `vendor-staged-sleep.md`.
- The gen4 byte-5 claim is single-source; the sleep-only measurement reports
do NOT contradict it (a realtime packet can carry SpO2 only during sleep,
which is consistent with the claim). It stays unverified because it has one
source and no ground-truth validation.
- No project anywhere publishes a live (daytime) SpO2 for any WHOOP
generation. The realistic product surface is a nightly sleep SpO2 for
5/MG, plus at most a raw/diagnostic byte for gen4.
- All sources agree the raw ADC channels cannot yield SpO2; any PR deriving %
from red/IR on 4.0 contradicts our own verified findings and should be
rejected.
- Relation to merged PR #472: its import surface already owns the `spo2`
MetricSpec (suppressed row, vendor-import provenance, not charted). Live
band-derived SpO2 must NOT create a second `spo2` row or chart key —
provenance (vendor import vs band-derived) stays separate. Our raw capture
(`Sample.spo2CandidateRaw`) is deliberately unread until the gate passes;
Comment thread
coderabbitai[bot] marked this conversation as resolved.
Resolved
the single publication path afterwards is `Spo2Data` in
`lib/models/payloads.dart`.
Comment thread
coderabbitai[bot] marked this conversation as resolved.
Resolved

## Staged plan (proposed)

1. **protocol** — raw, gated decode only:
- Keep `spo2CandidateRaw` as-is; add a pinned, documented interpretation
(bit 7 flag, value = low 7 bits) behind a plausibility gate, still
labeled candidate until validated.
- Add a decoder for the 96-byte realtime packet exposing byte 5 as **raw +
CRC flag only** — no percentage publishing. Resolve the characteristic
UUID discrepancy from real captures first.
- Tests from real frames; extend parity fixtures where applicable.
Comment thread
coderabbitai[bot] marked this conversation as resolved.
Resolved
2. **whoop-rs** — DEFERRED. Current scope is `protocol` + `edge` + `analytics`
(analytics owns the nightly metric, see step 3); only whoop-rs is out of
scope for now. When picked up: mirror the decoders in `whoop-protocol` (live 96-byte packet,
v18 byte 82 interpretation), expose raw values via `whoop-ffi`; keep the
existing `spo2_pct` v18 and `spo2_from_paired` paths unchanged.
3. **edge** — pass through the band-reported `deviceSpo2` samples for
gen5/5.0/MG; the per-burst medians and the nightly mean are computed in
`OpenStrap/analytics` (a metric, not signal wiring — AGENTS.md assigns
metrics there), labeled as a device estimate, same labeling discipline as
`vendor_staged`.
- After the gate passes: feed `Sample.spo2CandidateRaw` into `Spo2Data`
(`lib/models/payloads.dart`) as the single publication path — no separate
display path, no second `spo2` metric row (see #472 note above).
Comment thread
coderabbitai[bot] marked this conversation as resolved.
Resolved
- NO user-facing display on either generation until the validation
workstream lands: gen5 byte 82 stays raw until its encoding (bit-7 flag)
is pinned and validated against a reference device; gen4 byte 5 stays
diagnostic, never user-facing, until ground-truth validated.
- Diagnostics stay RAM-ONLY, never in `_log`/FileLog. FileLog persists to
Android external storage (`lib/sync/file_log.dart`): on Android ≤10 other
apps with storage permission can read it (CWE-532), and on 11+ the
app-specific dir is no longer cross-app readable — but the data would
still be PERSISTED, which is the primary reason health diagnostics stay
in RAM.
- Respect invariants: live streams RAM-only (inv. 14), never fabricate a
Comment thread
sourcery-ai[bot] marked this conversation as resolved.
Resolved
metric (inv. 3), bump `kAlgoVersion` when any output changes (inv. 4).
4. **Validation workstream** (prerequisite for ANY user-facing SpO2 value,
both generations): paired measurements against a reference oximeter over
at least 10 nights / 30 paired samples; the display gate opens only when
accuracy criteria are met — MAE <= 2 pp AND |mean bias| <= 1 pp AND
Comment thread
coderabbitai[bot] marked this conversation as resolved.
Resolved
Bland-Altman 95% limits of agreement within +/-4 pp. Correlation
Comment on lines +132 to +135

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

🟡 Medium · Validation can pass one wearer

When the minimum capture requirement is met using repeated measurements from one or a few wearers, the stated 10-night/30-sample gate sets no minimum number of participants or confidence requirement for the accuracy limits. A single wearer’s repeated pairs can therefore satisfy the gate without establishing accuracy across users, and the proposal presents that result as sufficient to unlock display to users.

Specify representative multi-participant coverage and require uncertainty bounds for the accuracy criteria before opening the display gate.

Prompt for AI agents
In `docs/proposals/whoop-spo2.md` at lines 109-112:

**Validation can pass one wearer**

When the minimum capture requirement is met using repeated measurements from one or a few wearers, the stated 10-night/30-sample gate sets no minimum number of participants or confidence requirement for the accuracy limits. A single wearer’s repeated pairs can therefore satisfy the gate without establishing accuracy across users, and the proposal presents that result as sufficient to unlock display to users.

Specify representative multi-participant coverage and require uncertainty bounds for the accuracy criteria before opening the display gate.

(Pearson/Spearman) is reported separately and is NEVER treated as proof of
accuracy. Burst-level pairs are NOT sufficient: the gate must also compare
the actual NIGHTLY OUTPUT (our aggregation over the band-declared sleep
window, burst weighting included) against the reference aggregated over the
same night, because burst-level agreement can pass while the nightly
Comment thread
coderabbitai[bot] marked this conversation as resolved.
Resolved
calculation uses the wrong window or weights. COVERAGE REQUIREMENT (else a
constant estimate passes by construction): reference samples must span the
saturation range (e.g. stratified bins across 85–100%) and participants must
be representative (FDA oximeter guidance explicitly calls out skin
pigmentation); accuracy is assessed per range/group, and a degenerate
constant estimate (all reference samples ~97%) must NOT open the gate.
Comment thread
coderabbitai[bot] marked this conversation as resolved.
Resolved
BURST COVERAGE: the reference must provide time-aligned readings for EVERY
burst used in the nightly aggregate — sparse reference samples can match the
nightly device output while missing errors during most of the night — and
MINIMUM SLEEP-WINDOW COVERAGE must be defined with an independent check for
omitted bursts before approving a nightly estimate (data loss leaving only a
few bursts must not pass the gate). WINDOW MEMBERSHIP: included/excluded
bursts are checked independently against the band-declared sleep boundaries,
and the reference aggregate is constructed from the correct window — two
aggregates sharing the same WRONG window can match each other. WEIGHTS: the
expected burst weights are defined independently and the implementation is
checked against them; the reference aggregate must NOT copy the device's
weights (e.g. bursts of 90/90/99 with weights 1/1/8 yield 97.2 instead of
the equal-weight mean 93 — a weighting defect the copied weights would
conceal). Gen4 has NO nightly SpO2 output —
its byte 5 is a live-stream byte only — so any Gen4 display gate must
instead use time-aligned LIVE reference measurements (same accuracy
thresholds: MAE <= 2 pp, |bias| <= 1 pp, 95% LoA within +/-4 pp), never the
nightly gate. If Gen4 LATER gains a nightly metric (in-memory aggregate over
a validated sleep window), that nightly output must be validated exactly
like the Gen5 one — against the reference aggregated over the same window —
because accurate live samples alone cannot detect wrong window selection or
weighting. Plus: byte-82 encoding pin-down, UUID discrepancy resolution.

## Publication path after the gate (explicit)

The gate and the publication path are separate concerns; both are specified
here so the gate is evaluable without shipping a display:

- **Validation-only read is allowed BEFORE the gate passes.** Evaluating the
gate requires the actual nightly output, so the same nightly aggregation
intended for publication is computed and compared against the reference —
internally only. User-facing output stays withheld until the gate passes;
`Sample.spo2CandidateRaw` remains unread by the UI in the meantime.
- **Payload changes (edge `payloads.dart`):** `Spo2Data` currently has no
percentage accessor and `TodayData.spo2` returns null while `odi_per_hour`
is null. Publication therefore adds: a `spo2Pct` field on `Spo2Data`, a
`double? get spo2Pct` accessor, and a getter condition on `TodayData.spo2`
that accepts the payload once validation has passed (flagged by the
validation record, not by the mere presence of a byte).
- **UI integration:** publishing through `Spo2Data` alone does NOT display
anything — the chart reads `metric_series` and the Explore row stays hidden
without stored `spo2` history. The integration step therefore writes the
validated nightly value into the existing `spo2` series with
band-derived provenance, reusing the #472 import row's provenance axis —
NO second `spo2` row, no second chart key.

## Out of scope

- Any medical claim or diagnosis (terms.html: wellness only, not a medical
device).
- Deriving SpO2 from red/IR ADC counts.
- Persisting live-stream data.