[Battery pak] "Current" shows the previous level; "Remaining" stuck on "calculating" after sleep #902
⚠️AI-assisted report. Written by an AI coding agent (Claude Code) under my direction; the device checks are mine.
Device: Anbernic RG SP (h700), Base OS 1.5.3, NextUI 6.15.0. The pak code is shared, so every platform is affected.
The Battery pak's "Current" disagrees with the status-bar pill, usually by one step and by much more after a sleep. Right after a 15 h sleep: pill 74, "Current: 83%", "Remaining: calculating".
Cause: batmon logs each new level with duration 0 and fills it in at the next change or after 10 min. compute_graph() in workspace/all/battery/battery.c takes the newest row whose duration is already non-zero, i.e. the previous level. The same stale row overwrites the right edge of the graph, which the "Remaining" slope reads, so the estimate overshoots the 15 h cap and shows "calculating".
Also noted in the comments on #867 ("the number you can find in the battery app is rarely the same").