Description

@NeJo123

Link

https://www.immax.sk/immax-neo-smart-controller-stmievatelny-v9-2-tlacidlovy-zigbee-3-0-p24247/

Database entry

{"id":17,"type":"Router","ieeeAddr":"0xa4c138fa923f4357","nwkAddr":64677,"manufId":4417,"manufName":"_TZ3210_j4tasjju","powerSource":"Mains (single phase)","modelId":"TS110E","epList":[1,2,242],"endpoints":{"1":{"profId":260,"epId":1,"devId":257,"inClusterList":[5,4,6,8,57345,4096,3,0],"outClusterList":[25,10],"clusters":{"genBasic":{"attributes":{"modelId":"TS110E","manufacturerName":"_TZ3210_j4tasjju","powerSource":1,"zclVersion":3,"appVersion":68,"stackVersion":0,"hwVersion":1,"dateCode":""}},"genOnOff":{"attributes":{"32770":0,"61440":0,"onOff":0,"moesStartUpOnOff":1}},"genLevelCtrl":{"attributes":{"61440":392,"64515":10,"64516":1000}}},"binds":[],"configuredReportings":[],"meta":{}},"2":{"profId":260,"epId":2,"devId":257,"inClusterList":[5,4,6,8,57345,5,4],"outClusterList":[],"clusters":{"genOnOff":{"attributes":{"61440":0,"onOff":1}},"genLevelCtrl":{"attributes":{"61440":392,"64515":10,"64516":1000}}},"binds":[],"configuredReportings":[],"meta":{}},"242":{"profId":41440,"epId":242,"devId":97,"inClusterList":[],"outClusterList":[33],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}}},"appVersion":68,"stackVersion":0,"hwVersion":1,"dateCode":"","zclVersion":3,"interviewCompleted":true,"interviewState":"SUCCESSFUL","meta":{"configured":332242049},"lastSeen":1790893781908}

Zigbee2MQTT version

2.14.1 (unknown)

External converter

// Immax 07582L / TS110E / _TZ3210_j4tasjju
// Target: Zigbee2MQTT 2.14.1 (zigbee-herdsman-converters 26.105.0).
// Inspired by the upstream TS110E_2gang_1 definition:
// https://github.com/Koenkk/zigbee-herdsman-converters/blob/v26.105.0/src/devices/tuya.ts
// Device evidence: endpoint 1, genOnOff attribute 0x8002 was read as 1,
// written as ENUM8 0, and read back as 0. Power-cycle testing is still required.

import * as m from 'zigbee-herdsman-converters/lib/modernExtend';
import {presets as e} from 'zigbee-herdsman-converters/lib/exposes';

const startupAttribute = 0x8002;
const startupValues = {off: 0, on: 1, previous: 2};

// A single setting, like the reference definition. Pin it to endpoint 1,
// where support was verified; do not advertise untested endpoint-2 settings.
const startupToZigbee = {
    key: ['power_on_behavior'],
    convertSet: async (_entity, _key, value, meta) => {
        if (!Object.hasOwn(startupValues, value)) {
            throw new Error('power_on_behavior must be off, on or previous');
        }
        const endpoint = meta.device.getEndpoint(1);
        await endpoint.write('genOnOff', {
            [startupAttribute]: {value: startupValues[value], type: 0x30},
        });
        // A read request also verifies the value on the device.
        const response = await endpoint.read('genOnOff', [startupAttribute]);
        const actual = response[startupAttribute] ?? response.moesStartUpOnOff;
        if (actual !== startupValues[value]) {
            throw new Error(`Power-on behavior verification failed: expected ${startupValues[value]}, received ${actual}`);
        }
        return {state: {power_on_behavior: value}};
    },
    convertGet: async (_entity, _key, meta) => {
        await meta.device.getEndpoint(1).read('genOnOff', [startupAttribute]);
    },
};

const startupFromZigbee = {
    cluster: 'genOnOff',
    type: ['attributeReport', 'readResponse'],
    convert: (_model, msg) => {
        if (msg.endpoint.ID !== 1) return;
        const raw = msg.data[startupAttribute] ?? msg.data.moesStartUpOnOff;
        const value = {0: 'off', 1: 'on', 2: 'previous'}[raw];
        if (value !== undefined) return {power_on_behavior: value};
    },
};

export default {
    fingerprint: [{modelID: 'TS110E', manufacturerName: '_TZ3210_j4tasjju'}],
    model: '07582L',
    vendor: 'Immax',
    description: 'NEO V9 two-channel switch',
    extend: [
        m.deviceEndpoints({endpoints: {'1': 1, '2': 2}}),
        m.onOff({
            endpointNames: ['1', '2'],
            powerOnBehavior: false,
            configureReporting: true,
        }),
    ],
    fromZigbee: [startupFromZigbee],
    toZigbee: [startupToZigbee],
    exposes: [e.power_on_behavior(['off', 'on', 'previous'])],
};

What does/doesn't work with the external definition?

Working:

  • Both output channels can be switched ON and OFF independently.
  • The exposes are no longer duplicated.
  • Power-on behavior works through genOnOff attribute 0x8002 on endpoint 1.
  • Attribute 0x8002 was successfully read, written and read back.
  • Power-on behavior mapping is: 0 = off, 1 = on, 2 = previous.

Not working:

  • Dimming could not be confirmed on this device.
  • The TS110E_2gang_1 brightness converter produced no observable physical brightness change.
  • The TS110E_2gang_2 converter was rejected with: UNSUP_COMMAND genLevelCtrl:moveToLevelTuya.
  • A direct standard genLevelCtrl:moveToLevel command completed without an error and Zigbee2MQTT published the requested brightness optimistically, but no physical brightness change occurred.

The submitted converter therefore intentionally exposes only two ON/OFF channels and one power-on behavior setting.

Image

Notes

software_build_id: undefined
date_code: ``
endpoints:

{"1":{"clusters":{"input":["genScenes","genGroups","genOnOff","genLevelCtrl","57345","touchlink","genIdentify","genBasic"],"output":["genOta","genTime"]},"name":"1"},"2":{"clusters":{"input":["genScenes","genGroups","genOnOff","genLevelCtrl","57345","genScenes","genGroups"],"output":[]},"name":"2"},"242":{"clusters":{"input":[],"output":["greenPower"]}}}